LONG-TERM STORAGE
Before performing any storage procedures
within this section, review the Safety section
on page 3.
If the engine will not be used for an extended
period of time, special measures should be
taken to protect the cooling system, fuel
system and combustion chamber from
corrosion and the exterior from rusting.
The engine can normally stand idle for up to
six months. If it remains unused for longer
than this, please contact your authorized
Yanmar Marine dealer or distributor.
PREPARE ENGINE FOR
LONG-TERM STORAGE
NOTICE: NEVER drain closed cooling
system for long-term storage.
Antifreeze must be used to avoid
freezing and damaging of components.
Antifreeze will prevent rusting during
long-term storage.
Note: If the engine is close to a periodic
maintenance interval, perform those
maintenance procedures before putting the
engine into long-term storage.
1. Wipe off any dust or oil from the outside
of the engine.
2. Drain any water from fuel filters.
3. Drain the fuel tank completely or fill the
tank to prevent condensation.
4. Drain the cooling system. (See Draining
the Cooling System on page 66.)
5. Grease the exposed areas and joints of
the remote control cables and the
bearings of the throttle and shift control
handle.
6. Seal the intake silencer, exhaust pipe,
etc., to prevent moisture or
contamination from entering engine.
7. Completely drain the bilge in the hull
bottom.
8. Waterproof the engine room to prevent
rain or seawater from entering.
9. Charge the battery once a month to
compensate for the battery’s self-
discharge.
GM Series Operation Manual 65