PERIODIC MAINTENANCE
6LPA Series Operation Manual 61
12/05
Checking the Battery Electrolyte
Level (Serviceable Batteries Only)
WARNING
Batteries contain sulfuric acid. NEVER
allow battery fluid to come in contact
with clothing, skin or eyes. Severe
burns could result. ALWAYS wear
safety goggles and protective clothing
when servicing the battery. If battery
fluid contacts the eyes and / or skin,
immediately flush the affected area with
a large amount of clean water and
obtain prompt medical treatment.
NOTICE
NEVER turn off the battery switch (if
equipped) or short the battery cables
during operation. Damage to the electric
system will result.
Note: Battery fluid tends to evaporate
in high temperatures, especially
in summer. In such conditions,
inspect the battery earlier than
specified.
1. Turn the battery master switch to OFF
(if equipped) or disconnect the negative
(-) battery cable.
2. Do not operate with insufficient battery
electrolyte as the battery will be
destroyed.
3. Remove the plugs and check the
electrolyte level in all cells.
NOTICE
NEVER attempt to remove the covers or
fill a maintenance-free battery.
4. If the level is lower than the minimum fill
level (Figure 7), fill with distilled water
(Figure 7) (available in the grocery
store) up to the upper limit (Figure 7) of
the battery.
WARNING
If operation continues with insufficient
battery fluid, the battery life is
shortened, and the battery may
overheat and explode.
Figure 7
Figure 7