LONG-TERM STORAGE
108 BY Series Operation Manual
8. Waterproof the engine room to prevent
rain or seawater from entering.
9. Charge the battery once a month to
compensate for battery’s
self-discharge.
10.Remove key from key switch and cover
key switch with moisture cap (if
equipped).
Drain Seawater Cooling System
IMPORTANT
If water fails to drain from any
open drain cock or port, remove
the cock completely and probe the
opening with a small piece of wire
to loosen debris.
Figure 1
1. Open the lower seawater drain cock
(Figure 1, (1)) located in the piping
between the seawater pump and
hydraulic oil cooler. Allow to drain.
2. Open the drain cock (Figure 1, (2)) on
the bottom of the charge air cooler.
0003659
(1)
(3)
(2)
(4)
(5 )
0003655